PM-II MYRINET CONF(5) |
|
PM-II MYRINET CONF(5) |
SymbolicSwitchName SwitchType
M2F-SW8 0 1 ... 7 M2M-DUAL-SW8 0A 0B 1A 1B ... 7A 7B M2M-OCT-SW8 0,0 0,1 ... 3,2 3,3 4,4 5,4 ... 6,7 7,7 or 0A 0B ... 7A 7B
NodeNumber Hostname SwitchNumber.PortNumber NodeNumber Hostname SymbolicSwitchName.PortName
switch SwitchNumber.PortNumber SwitchNumber.PortNumber switch SymbolicSwitchName.PortName SymbolicSwitchName.PortName
search SwitchNumber PortNumber PortNumber ...
# # Sample configuration file # # # Host specification # NodeNumber Hostname switchNumber.portNumber 0 comp0.pccluster.org 0.0 1 comp1.pccluster.org 0.1 2 comp2.pccluster.org 1.0 3 comp3.pccluster.org 1.1 # # Switch specification # switch switchNumber.portNumber switchNumber.portNumber switch 0.2 1.2 switch 0.3 1.3 # # Routing specification # search switchNumber portNumber ... search 0 0 2 1 3 search 1 0 2 1 3 # # End of configuration #以下は同じコンフィギュレーションをシンボリックスイッチ名とスイッチタイプ M2M-OCT-SW8 を使用して定義したものです:
# # Sample configuration file # # # Symbolic switch specification # SymbolicSwitchName SwitchType sw0 M2M-OCT-SW8 sw1 M2M-OCT-SW8 # # Host specification # NodeNumber Hostname SymbolicSwitchName.PortName 0 comp0.pccluster.org sw0.0,0 1 comp1.pccluster.org sw0.0,1 2 comp2.pccluster.org sw1.0,0 3 comp3.pccluster.org sw1.0,1 # # Switch specification # switch SymbolicSwitchName.PortName SymbolicSwitchName.PortName switch sw0.4,4 sw1.4,4 switch sw0.5,4 sw1.5,4 # # End of configuration #
シンボリックスイッチ名が定義されていて、スイッチ間で複数のルートが利用できる場合、ルート検索順序を設定することはできません。ルート検索の方針はスイッチタイプ M2M-OCT-SW8 によって自動的に決定されます。