If error messages about PM message library, set PM_DEBUG variable to 1 and run the same command again.
Following messages are not all of the error messages of PM communication
library, but well-displayed messages.
Ctgy |
Meassge |
Description |
Env |
"pmGetTypeList("%s", "%s"): no memory" |
malloc failed, no memory available. Check free memory. |
Config |
"pmOpenDevice("%s", %d, %p, %p): pm_get_device("%s"):
no such type" |
Specified Network devive was not found. Check network
device name. |
Config |
"pmAttachContext("%s", %d, %p): pm_get_device("%s"):
no such type" |
Specified Network devive was not found. Check network
device name. |
Config |
"pmGetOptionBit("%s", %p): no option %s" |
No specified option was found. Check option name. |
Ctgy |
Meassge |
Description |
Hard |
"[%d] %s: ** CRC error occurred (%d) on PM/Myrinet
**", |
CRC error occurred in myrinet network. This is not
serious error because the message is discarded and re-trasnmitted. However
the CRC error make performance problems, so check myrinet hardware. |
Hard |
"[%d] %s: ** SRAM Parity Error occurred (%d) on
PM/Myrinet **", |
SRAM Parity error occurred on the node number[%d],
check Myrinet NIC on the node as soon as possible. |
Config |
"myriReadConfig(%p, "%s"): cannot open %s", |
The specified file can not be opened. Be sure the
file on the directory. |
Config |
"myriReadConfig(%p, "%s"): line %d: Syntax Error", |
There is a sytax error in pm-myrinet.conf file.
Check pm-myrinet.conf |
Config |
"myriRegisterLink(%p, %d, "%s", "%s", "%s"): node
format error "%s"", |
There is a format error in pm-myrinet.conf file.
Check pm-myrinet.conf |
Config |
"myriRegisterLink(%p, %d, "%s", "%s", "%s"): node
number conflict "%d %s:%d"", |
Another node entry uses the number. Fix the node
number. |
Config |
"myriRegisterLink(%p, %d, "%s", "%s", "%s"): node
name conflict "%d %s:%d"", |
Another node entry uses the same node name. Fix
the node number. |
Soft/Hard |
"myriCheckLANai(%p, %x): timeout", |
PM/Myrinet library failed to synchronize with firmware
on of Myrinet NIC. Check the myrinet hardware. |
Hard |
"myriCheckLANai(%p, %x): link down", |
Myrinet cable of the node is not connected to switch
or node. This message is only outout Myrinet card with LANai 7 processors.
|
Config |
"myriCheckLANai(%p, %x): version miss match", |
The version of myrinet user library is not match
with firmware on the myrinet NIC. Check the version of library and firmware.
|
Config |
"myri_is_reachable(%p, %p): myriGetNodeByName(%p,
%s, %p): %s", |
The specified node is not on the pm-myrinet.conf.
Check the pm-myrinet.conf |
Ctgy |
Meassge |
Description |
Config |
"pmEthernetReadConfig(%p, "%s"): cannot open Configuration
file. (%d)", |
The specified file can not be opened. |
Config |
"pmEthernetReadConfig(%p, %s, %s, %s): node number
"%d" conflict", |
The node number is duplicated. Check pm-ethernet.conf
file. |
Config |
"pmEthernetReadConfig(%p, %s, %s, %s): node name
conflict "%s"", config, |
The node name is duplicated. Check pm-ethernet.conf
file. |
Config |
"pmEthernetConfigure("%s", %p): node hostname (%s)
is not found in configuration file (%d)", |
The node name is not found in pm-ethernet.conf.
Check pm-ethernet.conf file. |
Config |
"pmEthernetRegisgterDevice(%p) PNODESET: set_self
MAC address mismatch between configuration file and eth device ", |
The MAC address in pm-ethernet.conf of the node
is not same as the MAC address of the network interface, such as eth0. Check
pm-ethernet.conf file. |
![]() |
PCクラスタコンソーシアム |